13681860506 info@snslnk.com

High-Temperature Pressure Transmitter

PI700

With condensate syphon and heat-dissipating body, measures media up to 350 ℃.

Measurement type
表压
Range
0~100 kPa … 0~40 MPa
Overload
200% FS
  • ✓ Wet-calibrated before dispatch with a calibration record
  • ✓ Standard models ship in 5 working days; customised in as little as 10
  • ✓ Full technical support from selection through commissioning

With condensate syphon and heat-dissipating body, measures media up to 350 ℃.

Overview

With condensate syphon and heat-dissipating body, measures media up to 350 ℃.

Features

  • Integrated condensate syphon — no extra pipework for steam duty
  • Heat-dissipating body keeps the sensing element cool
  • Suits steam headers and thermal-oil systems
  • Optional extended impulse line for varying insulation thickness
  • Field-adjustable zero and span

Typical Applications

  • Steam headers and boilers
  • Thermal-oil and heat-transfer systems
  • Asphalt and molten materials
  • High-temperature reactor jackets

Selection Notes

The above reflects the standard configuration. Final selection depends on media properties, operating temperature and pressure, and environmental conditions. For special requirements, please contact our engineers for tailored advice. Technical parameters are subject to the final supply agreement.

Measurement type 表压
Range 0~100 kPa … 0~40 MPa
Overload 200% FS
Accuracy ±0.5% FS
Long-term stability ±0.2% FS / 年
Output signal 4~20mA 两线制
Power supply 12~36 VDC
Process connection M20×1.5 + 冷凝弯管
Diaphragm material 316L + 隔热组件
Media temperature -40~350 ℃
Ambient temperature -30~80 ℃
Ingress protection IP65
Electrical connection M20×1.5 电缆入口 / 赫斯曼接头
Load resistance ≤ (U-12V)/0.02A Ω

Note: the above reflects the standard configuration. Final selection depends on media and site conditions; parameters are subject to the supply agreement.

Features

  • Integrated condensate syphon — no extra pipework for steam duty
  • Heat-dissipating body keeps the sensing element cool
  • Suits steam headers and thermal-oil systems
  • Optional extended impulse line for varying insulation thickness
  • Field-adjustable zero and span

Typical Applications

  • Steam headers and boilers
  • Thermal-oil and heat-transfer systems
  • Asphalt and molten materials
  • High-temperature reactor jackets
Enquiry

Enquire About This Product

Leave your process conditions and we will respond with selection advice and a quotation within 24 hours.

Product