Integrated Temperature Transmitter
Pt100 element and transmitter module integrated in one body, delivering a standard 4–20 mA signal.
- Sensing element
- Pt100 铂电阻
- Calibration
- Pt100 (A级)
- Measuring range
- -50~200 ℃
- ✓ Wet-calibrated before dispatch with a calibration record
- ✓ Standard models ship in 5 working days; customised in as little as 10
- ✓ Full technical support from selection through commissioning
Pt100 element and transmitter module integrated in one body, delivering a standard 4–20 mA signal.
Overview
Pt100 element and transmitter module integrated in one body, delivering a standard 4–20 mA signal.
Features
- Element and transmitter integrated for high noise immunity
- 2-wire 4–20 mA, direct to PLC/DCS
- Field-configurable range reduces spare-part variety
- Sheathed protection tube resists vibration and shock
- IP65 terminal head for humid plant rooms
Typical Applications
- Water treatment and district heating
- Food sterilisation and cooling
- HVAC temperature control
- General industrial process measurement
Selection Notes
The above reflects the standard configuration. Final selection depends on media properties, operating temperature and pressure, and environmental conditions. For special requirements, please contact our engineers for tailored advice. Technical parameters are subject to the final supply agreement.
| Sensing element | Pt100 铂电阻 |
|---|---|
| Calibration | Pt100 (A级) |
| Measuring range | -50~200 ℃ |
| Accuracy | ±0.15 ℃ @ 0℃ (A级) |
| Output signal | 4~20mA 两线制 |
| Power supply | 12~36 VDC |
| Sheath material | 304 不锈钢 |
| Sheath diameter | Φ6 mm |
| Insertion length | 100 / 150 / 200 mm |
| Process connection | M20×1.5 活动卡套 |
| Pressure rating | ≤ 2.5 MPa |
| Ingress protection | IP65 |
| Response time | t0.5 ≤ 20 s |
Note: the above reflects the standard configuration. Final selection depends on media and site conditions; parameters are subject to the supply agreement.
Features
- Element and transmitter integrated for high noise immunity
- 2-wire 4–20 mA, direct to PLC/DCS
- Field-configurable range reduces spare-part variety
- Sheathed protection tube resists vibration and shock
- IP65 terminal head for humid plant rooms
Typical Applications
- Water treatment and district heating
- Food sterilisation and cooling
- HVAC temperature control
- General industrial process measurement
Related Products
Enquire About This Product
Leave your process conditions and we will respond with selection advice and a quotation within 24 hours.