Thermocouple Transmitter
Accepts type K/E/J/T thermocouples for measurement up to 1300 ℃.
- Sensing element
- K / E / J / T / S 型热电偶
- Calibration
- Pt100 (A级)
- Measuring range
- 0~1300 ℃(视分度号)
- ✓ Wet-calibrated before dispatch with a calibration record
- ✓ Standard models ship in 5 working days; customised in as little as 10
- ✓ Full technical support from selection through commissioning
Accepts type K/E/J/T thermocouples for measurement up to 1300 ℃.
Overview
Accepts type K/E/J/T thermocouples for measurement up to 1300 ℃.
Features
- Automatic cold-junction compensation removes ambient effects
- Multiple calibration types supported in one unit
- Ceramic protection tube resists high-temperature oxidation and corrosion
- Burnout up-drive alarm output on sensor failure
- Optional explosion-proof head for hazardous areas
Typical Applications
- Heat treatment and tempering furnaces
- Glass and ceramic kilns
- Boilers and incinerators
- Metallurgical melt measurement
Selection Notes
The above reflects the standard configuration. Final selection depends on media properties, operating temperature and pressure, and environmental conditions. For special requirements, please contact our engineers for tailored advice. Technical parameters are subject to the final supply agreement.
| Sensing element | K / E / J / T / S 型热电偶 |
|---|---|
| Calibration | Pt100 (A级) |
| Measuring range | 0~1300 ℃(视分度号) |
| Accuracy | ±0.5% FS 或 ±2.5 ℃ |
| Output signal | 4~20mA 两线制 |
| Power supply | 12~36 VDC |
| Sheath material | 刚玉 / 高铝陶瓷 / 316L |
| Sheath diameter | Φ16 / Φ20 / Φ25 mm |
| Insertion length | 100 / 150 / 200 mm 可选 |
| Process connection | M20×1.5 / 法兰 |
| Pressure rating | ≤ 2.5 MPa |
| Ingress protection | IP65 |
| Response time | t0.5 ≤ 20 s |
Note: the above reflects the standard configuration. Final selection depends on media and site conditions; parameters are subject to the supply agreement.
Features
- Automatic cold-junction compensation removes ambient effects
- Multiple calibration types supported in one unit
- Ceramic protection tube resists high-temperature oxidation and corrosion
- Burnout up-drive alarm output on sensor failure
- Optional explosion-proof head for hazardous areas
Typical Applications
- Heat treatment and tempering furnaces
- Glass and ceramic kilns
- Boilers and incinerators
- Metallurgical melt measurement
Related Products
Enquire About This Product
Leave your process conditions and we will respond with selection advice and a quotation within 24 hours.